New Research on Achromatic X-Ray Lens

2022-05-21 23:25:03 By : Mr. Yongde Wu

We use cookies to enhance your experience. By continuing to browse this site you agree to our use of cookies. More info.

High-performance X-ray optics are required for the non-invasive examination of the inner structure and elemental composition of matter at the micro-and nanoscale using X-ray technologies. Various types of reflecting, refractive, and diffractive optical elements have been created for this purpose over the previous few decades. This article will look at new research published in Nature Communications describing the development of an achromatic X-ray lens and its benefits.

Image Credit: Studio Peace/Shutterstock.com

Reflective X-ray optics use grazing incidence and complex geometries to produce a magnified image of an expanded field of vision, which results in long focal lengths that are inconsistent with a compressed setup.

Chester Moor Hall devised a method of dealing with chromaticity in the mid-eighteenth century by stacking a focusing lens made of crown glass and a defocusing lens made of flint glass to make an achromatic doublet.

Despite the significant chromaticity of each individual lens, a correct combination of the two lenses offered similar focal lengths for two distinct wavelengths and reduced chromatic aberration over the wavelength range between them, owing to the larger dispersion of flint glass than crown glass.

In contrast, chromaticity scales differently for refractive and diffractive X-ray lenses, which brings up the fundamental option of merging them to account for chromatic aberration and construct an X-ray achromat, as illustrated in Figure 1a.

Figure 1. Concept of the X-ray achromat and experimental setup. a principle of achromatic focusing: The chromaticity of the defocusing refractive lens (RL) acts as a corrector for the chromatic behavior of the focusing Fresnel zone plate (FZP). b Scanning electron microscopy (SEM) image of a nickel FZP fabricated by electron-beam lithography and nickel electroplating, as used for the comparison measurements. c SEM image of the RL consisting of four stacked paraboloids 3D-printed using two-photon polymerization lithography. d Sketch of the experimental setup for scanning transmission X-ray microscopy (STXM) and ptychography using the achromat as a focusing optic. Image Credit: Kubec, et al., 2022

An FZP was created using electron-beam lithography and nickel electroplating, and a 3D-printed RL was made using two-photon polymerization in the described X-ray achromat. With the experimental setup depicted in Figure 1d, the achromat was mounted as a focusing optic at the Swiss Light Source’s cSAXS beamline.

Instead of using the achromat, reference measurements were made with a regular FZP (as indicated in Figure 1b). The numerical aperture of both optics was the same, restricting the attainable spot size to roughly 500 nm.

The STXM pictures of the Siemens star test sample displayed in Figure 2b were collected with the achromat as a focusing optic at various X-ray energy, as indicated in Figure 2a.

When analyzing the achromat’s performance to STXM data acquired using the FZP as an optical element, the achromat’s huge advantage becomes obvious (as shown in Figure 2c).

Figure 2. Demonstration of STXM imaging at different energies using the achromat. a STXM images of the Siemens star sample shown in panel b obtained with the achromat, indicating an achromatic range of  > 1 keV around the optimum energy of ~ 6.4 keV. b SEM image of the Siemens star test sample. The radial lines and spaces (L/S) at the outer and inner concentric rings have widths of 400 nm and 200 nm, respectively, see red arrows. c Comparison of the STXM results in the energy range of 6.0 keV to 6.4 keV obtained with the achromat (top) and the conventional FZP (bottom). While the contrast of the FZP images changes rapidly with the energy, the image quality achieved with the achromat varies only little. Image Credit: Kubec, et al., 2022

Figure 3a shows cuts across the caustics of the achromat in the xz plane (Figure 1d), with the focus position indicated by a red dashed line. Figure 3b suggests a clear comparison of the caustics acquired with the achromat and the FZP, confirming the achromat’s large gain in the achromatic range, as seen in the STXM photos in Figure 2.

Figure 3. Evolution of the X-ray beam profile with the energy measured with ptychography. a Caustics at energies from 5.2 keV to 8.0 keV obtained with the achromat. The red dashed line indicates the location of the focal plane at the different energies. b Comparison of the caustics obtained with the achromat and the FZP. While the position of the focal plane remains almost constant with the energy for the achromat (red dashed line), it changes rapidly for the FZP (blue dashed line). c Calculated curves (solid and dashed lines) and experimental data (dots) for the focal length versus energy for the FZP (blue) and the achromat (red; solid: based on Eq. (6), dashed: based on tabulated refractive index values for the calculation of fRL at each energy). Image Credit: Kubec, et al., 2022

As shown in Figure 3c, the experimental results for the focus point placement accord well with the equivalent predicted curves for both the achromat and the FZP.

Figure 4a depicts the outcome of combining the binarized SEM picture of the Siemens star in Figure 2b with a simulated polychromatic X-ray beam with an energy range of 5.6 keV to 6.8 keV generated with an achromat. When contrasted to the image in Figure 4b, which was simulated analogously using a FZP as an optical element, the improvement in image quality is significant.

The simulated polychromatic beam profiles in Figure 4c show significantly better side lobes of the beam for the FZP than for the achromat, indicating an increase in picture quality.

Figure 4. Simulations of polychromatic X-ray focusing with an achromatic lens and with a single FZP (energy range from 5.6 keV to 6.8 keV). a Convolution of the simulated polychromatic X-ray beam of the achromat with the binarized image of the Siemens star in Fig. 2b. b Convolution of the same image with the simulated polychromatic X-ray beam of the FZP. Gaussian noise was added to both images after convolution to model the image noise in experimental data. c Line profiles of the simulated polychromatic X-ray beams (normalized to central peak) for the achromat (red) and the FZP (blue). Image Credit: Kubec, et al., 2022

The experimental realization of an X-ray achromat comprised of a concentrating diffractive and a defocusing refractive optical element that delivers consistent imaging performance throughout a large energy range without changing the focal settings has been described. This feature will aid monochromatic X-ray investigations that require a quick or frequent shift in photon energy.

According to the models, the achromat will be especially useful for its application in polychromatic laboratory X-ray tube sources, allowing for efficient high-resolution imaging in laboratory-based X-ray systems.

The FZP that was employed as part of the achromat was a four-step, double-sided blazed FZP. It was made up of nickel structures on the top and bottom of a silicon nitride membrane with a thickness of 250 nanometers.

The membranes were overlaid with a chromium-gold-chromium plating base by evaporation for both FZPs, and then spin-coated with a Poly(methyl methacrylate) (PMMA) resist layer, which was then revealed by electron-beam lithography. The designs were created, the resist trenches were cleansed by plasma etching, and then the nickel was electroplated, followed by the removal of the remaining PMMA.

By using Nanoscribe Photonic Professional GT, the RL was 3D-printed employing two-photon polymerization-induced lithography.

An SEM image of the RL used in the experiment is shown in Figure 1c. To stack the four paraboloids, vertical support structures were printed.

The achromat was created in such a way that the RL served as a corrector for the FZP’s chromaticity. The result of the diffraction performance of the FZP and the X-ray transmission through the RL may be used to approximate the efficiency of such an achromat, yielding a theoretical efficiency of roughly 24% at the design energy of 6.2 keV for the optics.

Figure 1d depicts the experimental setup for the measurements. The beam-shaping slits upstream of the setup were designed to guarantee that the lens aperture was illuminated totally coherently.

X-ray ptychography has emerged as a useful tool for characterizing X-ray optics in the recent decade. The approach was utilized to recover the caustics of the X-ray beam that illuminated the material in this case.

The coordinates of the voxel with the maximum intensity in each caustic are shown by the measured data points for focal length in Figure 3c.

Both an achromat, comprised of an RL and an FZP, and a single FZP were simulated for X-ray focusing. The simulations were carried out using Matlab code created in-house and based on an angular-spectrum technique reported in previous papers.

The simulations were carried out in stages of 50 eV for energies between 5.6 and 6.8 keV. Simulated X-ray pictures of a Siemens star were created using the X-ray probes acquired this way for both the achromat and the FZP. The SEM image of the Siemens star in Figure 2b was binarized and then convolved in the focus plane with the generated X-ray probe.

The work presented here is a proof-of-concept for an X-ray achromat, with room for further advancements in manufacturing methods and design. The reduced X-ray spot size will need RLs with greater refracting powers and, as a result, higher structures with smaller curvature radii.

This problem, as well as the RL’s considerable absorption losses, can be solved by designing the RL with a stepped profile, as previously described.

Additionally, while the diffractive and refractive components of the achromat are now installed on two distinct support membranes, researchers will investigate the manufacturing of the achromat as a single monolithic device in the future. This will make aligning and using the achromatic X-ray lens in the experimental setup much easier.

Kubec, A., Zdora, M. C., Sanli, U. T., Diaz, A., Vila-Comamala, J., David, C. (2022) An achromatic X-ray lens. Nature Communications, 13(1), pp. 1-7. Available Online: https://www.nature.com/articles/s41467-022-28902-8.

Laura Thomson graduated from Manchester Metropolitan University with an English and Sociology degree. During her studies, Laura worked as a Proofreader and went on to do this full time until moving on to work as a Website Editor for a leading analytics and media company. In her spare time, Laura enjoys reading a range of books and writing historical fiction. She also loves to see new places in the world and spends many weekends looking after dogs.

Please use one of the following formats to cite this article in your essay, paper or report:

Thomson, Laura. (2022, April 21). New Research on Achromatic X-Ray Lens. AZoOptics. Retrieved on May 21, 2022 from https://www.azooptics.com/Article.aspx?ArticleID=2200.

Thomson, Laura. "New Research on Achromatic X-Ray Lens". AZoOptics. 21 May 2022. <https://www.azooptics.com/Article.aspx?ArticleID=2200>.

Thomson, Laura. "New Research on Achromatic X-Ray Lens". AZoOptics. https://www.azooptics.com/Article.aspx?ArticleID=2200. (accessed May 21, 2022).

Thomson, Laura. 2022. New Research on Achromatic X-Ray Lens. AZoOptics, viewed 21 May 2022, https://www.azooptics.com/Article.aspx?ArticleID=2200.

Do you have a review, update or anything you would like to add to this article?

This product profile describes the properties and applications of the ProMetric® I-SC Solution Imaging Colorimeter.

The Filmetrics F20 benchtop film thickness measurement tool is a general purpose instrument for measuring thickness and refractive index.

Dynamic characterization of MEMs devices is achieved by Micro System Analyzer MSA-650 IRIS.

AZoOptics speaks to Dr. Keith Paulsen about the importance of breast cancer detection and the introduction of his team's deep-learning algorithm that associates spatial images of tissue optical properties with optical signal patterns measured during an imaging experiment or patient exam.

Prof. Simon Scheuring & Dr. Alma P. Perrino

AZoOptics speaks to Prof. Simon Scheuring & Dr. Alma P. Perrino about their recent research using a new line-scanning high-speed atomic force microscopy technique. The method helps characterize the single-molecule kinetics of wild-type bR (bR-WT) exposed to continuous light and short light pulses.

AZoOptics interviews R. Bruce Weisman from Rice University in Texas, US, who has discovered fluorescence from silicon nanoparticles in cement and how it can be used to reveal early signs of damage in concrete structures.

AZoOptics.com - An AZoNetwork Site

Owned and operated by AZoNetwork, © 2000-2022